ApplicationsThe Purair Advanced supports the following applications :
Capsule Filling, Chemical Sampling, Dental Labs, Drug & Chemical Analysis, Forensics, Histology, Ink Fumes, Light Grinding, Pharmaceutical, Pipetting, Slide Staining, Spray Adhesives, Weighing.
|
 |
 Product FeaturesA. Filter I.D. Window: A strategically placed front cover window shows the installed filter part number and installation date for convenience and to encourage timely filter replacement. B. Air Velometer: An analog air velocity meter in the field of vision of the user provides independent backup to the electronic airflow alarm. C. Double Hinged Self Locking Front Sash: When closed, the cabinet sash protects the operator with 100 FPM airflow. The sash is easy to open and latch. D. Control Panel: Electronic controls and displays include switches for the blower and lights, an electronic hour counter and low airflow alarm, all located on a convenient front surface panel. E. Steel Support Frame: The chemical resistant epoxy coated steel frame adds mechanical strength. Optional all polypropylene construction is available if desired. The pre-filter can be changed while the unit is operating to prevent operator exposure to chemical vapors. F. Electrostatic Pre-Filter: The A 99.5% effective electrostatic pre-filter is accessible from inside the chamber to contain the release of any particulates that it traps. G. Pass Through Ports: Electrical cords and cables are safely routed into the cabinet through ports on the back and side walls H. Air Sampling Port: A filtered air sampling port allows manual filter monitoring. I. Color: The cabinet is white; side and back panels are clear. J. Airflow Alarm: A continuous air velocity monitoring system alerts the operator upon unacceptable values. K. Manual Speed Controller: The operator may set the centrifugal fan motor speed as desired. L. Dynamic Filtration Chamber: The dynamic filter chamber prevents any possible leakage of contaminated air by pressurizing the fan plenum (positive air) and depressuring the filter compartment (negative air). M. Stand: Optional mobile cart with locking casters. N. Safety Filter: The optional carbon or HEPA/ULPA safety filter adds an additional layer of protection. O. Work Surface: The internal work surface can be fitted with an optional polypropylene tray; see Accessories. P. Filter Door Key: Filter access keys prevent unauthorized removal or accidental exposure to dirty filters. Q. Track & Wheel System: The filter glides in on a wheel and track system, then clamps tightly against the filter gasket to prevent filter tears and maintain filter integrity.
OTHER FEATURES:
360 Degree Visibility: Clear back and side panels allow ambient illumination into the chamber and provide users with an unobstructed view of its contents. Standards Compliant: Performance specifications and construction meet or exceed OSHA, ANSI and relevant international standards to assure operator safety. Construction: All models are available in either metal or polypropylene construction. See selection chart for specifi cations and dimensions. Specify metal or polypropylene when ordering. Available in 110v /60 Hz models.
Please note : The stand/cart is an optional product and is sold separately.
|
 |
Performance AdvantageEach Air Science fume hood includes features expressed through sound design and certified quality construction. Options and accessories add functional performance to meet specific applications.
Professional Quality. Air Science fume hoods comply with current technical and safety regulations.
Multiplex Filtration. The Air Science Multiplex Filter offers a range of options for high performance protection.
Industrial Components. The cabinet frame and work surfaces are durable and chemically resistant.
Reliability. Internal systems are isolated from fumes, extending product life.
|
 |
 Features and BenefitsPurair® Basic products are available in 3 standard sizes, each with 4 configuration options and metal or polypropylene construction, totaling 24 standard models.
(We currently only have a small range available)
High capacity air handling system delivers face velocity of 100 fpm.
A low airflow alarm warns of insufficient face velocity.
The Air Science® filter assembly is easy to access, easy to change.
A unique filter clamping design eliminates bypass leakage outside the cabinet.
Accessories include an optional filter saturation alarm.
|
 |
| Download the Air Science Purair Advanced Brochure by clicking the icon |  |
|
 |
 Purair Advanced SummaryThe Purair® Advanced Series ductless fume hoods are a series of high efficiency products designed to protect the user and the environment from hazardous vapors generated on the work surface. At the heart of the Purair® fume hood product line is the innovative Air Science® Multiplex Filtration Technology that creates a safe work environment over the widest range of applications in the industry.
DUCTLESS TECHNOLOGY: The Eco-friendly Choice
Advanced carbon filtration technology offers a safe, high performance alternative to conventional ducted fume hoods for a broad range of applications.
Environmental Benefits. Air Science® ductless fume hoods isolate and trap chemical vapors to prevent ecological impact through release into the environment.
Versatile. Each filtration system is selected for its specific application. The Multiplex Filter broadens the range of applications. Carbon filters are available in more than 14 configurations for use with vapors of organic solvents, acids, mercury, formaldehyde. HEPA/ULPA filters can be added for biological safety.
Easy to Install. The ductless fume hood is self-contained and does not require venting to the outside. Many units are portable and may be moved from one location to the next with minimal downtime and without filter changes. Set-up, operation and filter maintenance are straightforward.
Energy Efficient. Because filtered air is returned to the room, no demands are required of the facility HVAC capacity for make-up air.
Cost Effective. Facility ductwork, HVAC and construction costs are eliminated.
Safe to Use. Cabinet airflow and face velocity protect users from incidental exposures to fumes.
Self testing. (selected models) Electronic air flow monitoring assures continuous safety. An electronic gas sensor monitors carbon filter performance. |
 |
|
 |
|
 |
|
 |
|
 |
|
 |
|
 |
|
 |
|
 |
|
 |
|
 |
|
 |
|
 |
|
 |
|
 |
|
 |
|
 |
|
 |
|
 |
|
 |
|
 |